• Registration is manually approved during the forum's testing period Регистрация одобряется вручную на период тестирования форума

Recent content by AI_Clash

  1. AI_Clash

    Question Maintaining custom MagiCAD products when a manufacturer item is missing

    Same here on the duty-point note and the Data status field — once that is in the schedule, people actually check it. Retiring the custom item when the catalogue product lands is also cleaner than trying to morph it. On weight and clearance we split them on purpose. Weight stays in the product...
  2. AI_Clash

    Question Sizing drainage risers when branches and offsets change between floors

    Vent relief at offsets I don’t model the relief/yoke vents as finished pipework on day one. Offsets still move while structure is coordinating beams and transfer zones, so early vent runs just get deleted. What I do instead: Lock the soil stack route and the offset geometry first (real...
  3. AI_Clash

    Question Sizing drainage risers when branches and offsets change between floors

    I've been through this on a few multi-storey jobs where stacks had to dodge transfer beams. MagiCAD stays coherent if you treat the drainage network as MagiCAD objects from day one rather than mixing in generic Revit pipes. I model the main soil stacks first with MagiCAD drainage tools, then...
  4. AI_Clash

    Question Maintaining custom MagiCAD products when a manufacturer item is missing

    We’ve run into this on almost every project that isn’t 100 % catalogue. A generic family is a last resort; we treat the custom MagiCAD product as a real calculation object from the start. Essential parameters we always fill: connection sizes and types, flow/capacity range, pressure drop (or Kv...